Why is air sampling performed for 10 minutes to sample 1000 litres of air? Which USP chapter mentions this requirement?

Air sampling for 10 minutes for 1000 liters of air is a common practice based on USP Chapter <1116>, which addresses microbiological control and monitoring of aseptic environments. This standard outlines guidelines for assessing the microbiological quality of air in controlled environments. The 10-minute sampling duration ensures an adequate volume of air is tested to […]

Why is air sampling performed for 10 minutes to sample 1000 litres of air? Which USP chapter mentions this requirement? Read More ยป

Have you seen the TOC instrument in the water plant, and what limit is shown on the display?

The TOC instrument at water plant is showing a reading below 100 ppb, it indicates excellent water quality, as it’s well below the typical limit of 500 ppb set by theUSP for purified water or water for injection (WFI). This low level suggests that the water is effectively free of organic contaminants, which isideal for

Have you seen the TOC instrument in the water plant, and what limit is shown on the display? Read More ยป

๐—ช๐—ต๐—ฎ๐˜ ๐—ถ๐˜€ ๐˜๐—ต๐—ฒ ๐—น๐—ถ๐—บ๐—ถ๐˜ ๐—ผ๐—ณ ๐—ง๐—ข๐—–?

The limit of Total Organic Carbon (TOC) in pharmaceutical water systems, such as Purified Water (PW) and Water for Injection (WFI), is typically set at 500 ppb (parts per billion). This limit is specified in pharmacopeias like the USP (United States Pharmacopeia) and EP (European Pharmacopeia) to ensure water purity by controlling organic contamination levels.

๐—ช๐—ต๐—ฎ๐˜ ๐—ถ๐˜€ ๐˜๐—ต๐—ฒ ๐—น๐—ถ๐—บ๐—ถ๐˜ ๐—ผ๐—ณ ๐—ง๐—ข๐—–? Read More ยป

Why is SCDA not used for water testing?

SCDA (Soybean Casein Digest Agar), commonly used for general microbiological testing, isnot typically used for water testing because water testing generally requires specialized media that are designed to detect waterborne bacteria and other microorganisms. In water testing, specific media like R2A Agar, support the growth of bacteria that thrive in low-nutrient environments like water. Provide

Why is SCDA not used for water testing? Read More ยป

How much media is weighed for SCDA, and what is its pH? Why is pH measured before and after sterilization?

๐Œ๐ž๐๐ข๐š ๐–๐ž๐ข๐ ๐ก๐ญTypically, 40 g of SCDA powder is dissolved in 1 liter of distilled water. ๐ฉ๐‡The pH should be 7.3 ยฑ 0.2 at below 25ยฐC after and before sterilization.pH is measured before sterilization to ensure the media is properly prepared, and after sterilization to confirm the media’s suitability for use in culturing microorganisms. Sterilization can

How much media is weighed for SCDA, and what is its pH? Why is pH measured before and after sterilization? Read More ยป

Why is 70% IPA used instead of 100% IPA?

We use 70% Isopropyl Alcohol (IPA) instead of 100% because it is more effective at killing microorganisms. Pure alcohol evaporates too quickly to penetrate cell walls and denature proteins. 70% IPA has the right balance of water and alcohol, which allows it to stay on surfaceslonger, breaking down bacterial cell membranes more effectively ๐‡๐—ผ๐˜„ ๐—ฑ๐—ผ๐—ฒ๐˜€

Why is 70% IPA used instead of 100% IPA? Read More ยป

How many temperature probes are installed inside the autoclave for revalidation?

Revalidation of an autoclave typically requires 12 temperature probes strategically distributedthroughout the chamber to ensure uniform sterilization. Key probe placements include: This helps confirm that the autoclave consistently reaches and holds the required sterilizationtemperature. While the exact number of probes can vary depending on the autoclave size andvalidation protocol, data loggers are commonly used to

How many temperature probes are installed inside the autoclave for revalidation? Read More ยป